Wednesday, 18 November 2015
Skin Effect
The skin effect is predominant with the increase in the frequency . The skin depth is inversely proportional to the square root of the frequency.The frequency where the skin effect just start to limit the the effective cross sectional area of the conductor is called the crossover frequency.
Wednesday, 11 November 2015
Tertiary Winding
This is a special type of winding used generally in star-star transformer. It it wound on the limb of the Ns= 120/P transformer which the primary and secondary are wound. It Ns- synchronous speed
P- no. of Pole is also called stabilizing winding. It is always delta
connected. Its main function is to arrest the this
3rd Harmonic voltage
Pc ∝ F
Pc - Core Loss , F - Frequency
P- no. of Pole is also called stabilizing winding. It is always delta
connected. Its main function is to arrest the this
3rd Harmonic voltage
Pc ∝ F
Pc - Core Loss , F - Frequency
Sunday, 8 November 2015
Parallel Operation Single Phase (1Φ) Transformer
Condition :-
i) The frequency of both transformers which are in parallel must be same.
ii) The ratio of voltage of parallel contacts transformer must be equal. Otherwise a circulating current will be flow from higher potential to lower potential. This is only limited by the independence of those transformers if the ratio is larger different value of this current is also larger which may burnt the winding's of both transformer.
iii) Phase sequence of parallel connected transformer must be same. Otherwise line voltage will appear across the phase winding's.
iv) The transformer should be of same phasor group.
v) The ratio of per phase reactance Xe and Rc should be same both the transformer otherwise a circulating current will be flow .
Parallel Operation |
Advantages :-
1. If two and more transformer are connected in parallel the service continuity ensure and the system become reliable.
2. Any transformer can be switch off or depending on their load demand.
3. If more transformer works in parallel the chance of over loading of a particular transformer reduce.
4. The cost of stand by unit transformer is reduce.
Disadvantage :-
A. When one or more transformer works on parallel then chance of fault occurrence will increased.
B. The maintenance cost become more.
C. The space required for installing the transformer is more.
D. The protective device of transformer is more.
Thursday, 5 November 2015
Scott Connection / T Connection :-
This is a scott connection which convert 3 phase and 2 phase & vice versa if employs two identical transformers one with centre tap primary known as main transformer and the other with primary√ 3/2 tap known as teaser transformer . the main transformer primary centre tap D is connected with one end of the teaser primary as shown in the figure . Now ends A, B, C, are connected to three phase ac supply and two phase four wire supply is obtained.The two phase side makes use of all the turns on teaser winding as well as all the voltage per turns of the two transformer to be equal.
Application :-
The voltages in the primaries of two transformer are 90 (degree) phase displaced . So voltages in there secondary voltages will also 90 (degree) displaced i.e. 3 phase supply has been converted to 2 phase.If we interchange the position the load and supply 2 phase can be converted into 3 phase.
Subscribe to:
Posts (Atom)
Types of Loss in Power System / Energy losses
There are many types of losses in transmission line as follow... 1. Resestive loss 2. Inductive loss 3. Radiation loss 4. Eddy curren...
-
The losses occuring in the generator stator winding components viz stator winding, main brushes & phase connetors are dissipated d...
-
This is a scott connection which convert 3 phase and 2 phase & vice versa if employs two identical transformers one with centre tap...
-
Rated MVA rating MCR conditon- 247 MW Rated KVA rating MCR conditon- 210 MW Terminal Output Voltage- 15.75KV Rated Current- 9050 A P...