Thursday, 11 February 2016
INDUCTION GEMERATOR
The induction Generator not a self-generator. It is necessary to exite the stator an external source to rated voltage and frequency.it will genwrate only whenit is connected to a source to fixed voltage and frequency and if is then driven at a speed above the synchronous speed.
1. breaking Induction or magnetic
Thursday, 28 January 2016
PERCENTAGE DIFFFERENTIAL PROTECTION(MERZ-PRICE PROTECTION) FOR TRANSFORMER
The percentage differential protection or Merz-Price protection based on the circulating current principle can also be used for the transformer. This system gives protection against pass to phase faults to the power transformers.
The principle of such a protection scheme is the comparison of the currents entering and leaving the ends of transformer, two currents at the two ends of ends of the transformer are equal and balance is maintenance . So no current flows through the operating coil of the relay is inoperative .But when there is phase to phase fault , this balance gets disturbed. The difference current flows through the operating coil due to which relay operates, tripping the circuit breaker.
Compared to the differential protection used in generators, there are certain important points which must be taken care of while using such protection for the power transformer. These points are.
1. In a power transformer, the voltage rating of the two winding is different. The high voltage winding is low current winding while low voltage winding is high current winding. Thus there always exists difference in current on the primary and secondary sides of then relay may get operated through there is no fault existing.
To compensate for this difficulty, the current ratios of CT s. on each side are different. These ratios depend on the line current of the power transformer and the connection of CT s. Due to different turns ratio, the currents fed into the pilot wire from each end are same under normal conditions so that the relay remains inoperative
Thursday, 17 December 2015
Turbo Generator(TG) Specification 210 MW
Rated MVA rating MCR conditon- 247 MW
Rated KVA rating MCR conditon- 210 MW
Terminal Output Voltage- 15.75KV
Rated Current- 9050 A
Power Factor- 0.85 Lagging
Excitation Voltage- 310 V DC
Excitation Current- 2600 A
Stator Phase Connection- Star_Star
Rated Frequency- 50 Hz
Rated Speed- 3000 RPM
Cooling System- Stator_water (H2O)
Rotor_Hydrogen (H2)
Gas Pressure- 3.5 Kg/Cm
Type Of Insulation- Class B
No Of Terminal Brought Out- 9
Rotation Of Rotor- Anticlockwise(View on Slip ring end)
Over All Stator Dia- 3960 MM
Length Of Stator- 4580 MM
Weight Of Stator- 175,00 Kg
Length Of Rotor- 9770 MM
Weight Of Rotor- 42,200 KG
Rated KVA rating MCR conditon- 210 MW
Terminal Output Voltage- 15.75KV
Rated Current- 9050 A
Power Factor- 0.85 Lagging
Excitation Voltage- 310 V DC
Excitation Current- 2600 A
Stator Phase Connection- Star_Star
Rated Frequency- 50 Hz
Rated Speed- 3000 RPM
Cooling System- Stator_water (H2O)
Rotor_Hydrogen (H2)
Gas Pressure- 3.5 Kg/Cm
Type Of Insulation- Class B
No Of Terminal Brought Out- 9
Rotation Of Rotor- Anticlockwise(View on Slip ring end)
Length Of Stator- 4580 MM
Weight Of Stator- 175,00 Kg
Length Of Rotor- 9770 MM
Weight Of Rotor- 42,200 KG
Subscribe to:
Posts (Atom)
Types of Loss in Power System / Energy losses
There are many types of losses in transmission line as follow... 1. Resestive loss 2. Inductive loss 3. Radiation loss 4. Eddy curren...
-
The field winding of an alternator is placed on the rotor and is connected to DC supply for producing the magnetic flux through slip rings...
-
The losses occuring in the generator stator winding components viz stator winding, main brushes & phase connetors are dissipated d...
-
The percentage differential protection or Merz-Price protection based on the circulating current principle can also be used for the trans...